TMC Compressors
We have worked closely with our customers to develop the TMC marine compressors to ensure that functionality and design is optimal for installation and use onboard ships and offshore installations.
Shipbuilders appreciate the compact design of a TMC marine compressor because it saves time and installation costs, and make the most of vuluable space on board.
Shipowners like the performance, the easy maintenance and the low life-cycle costs.
TMC Smart Air Compressors
TMC Smart Air compressors utilize the latest energy saving technology. This means you can save up to 50% of your energy costs and help your ship become green!
View range
TMC Offshore and Topside Compressors
TMC’s Custom Engineered Compressors for offshore and topside installations have a capacity range of 10-55 m3/min and are approved for non-hazardous zone and EX zone 1 and 2 installations.
Read more
TMC Spare Parts & Service
Using TMC’s service team to assist you ensures optimal operation of your compressed air system. TMC’s original spare parts gives lower running costs and peace of mind at sea.
Read more

TMC Standard Compressors – Entire Range

Type and Motor KW Capacity (nom.press.) Capacity (nom.press.) Capacity (nom.press.) Nominal Pressure Max Pressure Nominal Pressure Max Pressure Weight Dimensions
m3/h m3/min c.f.m bar bar psi psi kg mm (WxHxD)
TMC 7-8 70.2 1.17 41.3 7 8 101.5 116.0 300 993 x 1256 x 728
TMC 7–10 60.9 1.02 35.8 9 10 130.5 145.0 300 993 x 1256 x 728
TMC 10–8 84.4 1.41 49.7 7 8 101.5 116.0 300 993 x 1256 x 728
TMC 10-10 72.1 1.20 42.4 9 10 130.5 145.0 300 993 x 1256 x 728
TMC 15-8 115.5 1.93 68.0 7 8 101.5 116.0 340 993 x 1256 x 728
TMC 15-10 103.5 1.73 60.9 9 10 130.5 145.0 340 993 x 1256 x 728
TMC 19-8 155.2 2.59 91.3 7 8 101.5 116.0 430 993 x 1256 x 728
TMC 19-10 136.4 2.27 80.3 9 10 130.5 145.0 430 993 x 1256 x 728
TMC 22-8 206.9 3.45 121.8 7 8 101.5 116.0 440 993 x 1256 x 728
TMC 22-10 170.9 2.85 100.6 9 10 130.5 145.0 440 993 x 1256 x 728
TMC 27-8 234.0 3.90 137.7 7 8 101.5 116.0 480 993 x 1256 x 728
TMC 27-10 205.7 3.43 121.1 9 10 130.5 145.0 480 993 x 1256 x 728
EMH 35-8 345.8 5.76 203.5 7 8 101.5 116.0 750 701 x 1700 x 1006
EMH 35-10 294.3 4.91 173.2 9 10 130.5 145.0 750 701 x 1700 x 1006
EMH 35-13 255.5 4.26 150.4 12 13 174.0 188.5 750 701 x 1700 x 1006
EMH 44-8 376.0 6.27 221.3 7 8 101.5 116.0 750 701 x 1700 x 1006
EMH 44-10 334.5 5.58 196.9 9 10 130.5 145.0 750 701 x 1700 x 1006
EMH 44-13 287.0 4.78 168.9 12 13 174.0 188.5 750 701 x 1700 x 1006
TMC 54-8 629.9 10.50 370.7 7 8 101.5 116.0 1455 1462 x 1952 x 1060
TMC 54-10 547.0 9.12 322.0 9 10 130.5 145.0 1455 1462 x 1952 x 1060
TMC 54-13 448.1 7.47 263.7 12 13 174.0 188.5 1455 1462 x 1952 x 1060
TMC 65-8 671.9 11.20 395.5 7 8 101.5 116.0 1460 1462 x 1952 x 1060
TMC 65-10 586.0 9.77 344.9 9 10 130.5 145.0 1460 1462 x 1952 x 1060
TMC 65-13 480.7 8.01 282.9 12 13 174.0 188.5 1460 1462 x 1952 x 1060
TMC 85-8 755.5 12.59 444.7 7 8 101.5 116.0 1550 1462 x 1952 x 1060
TMC 85-10 655.5 10.92 385.8 9 10 130.5 145.0 1550 1462 x 1952 x 1060
TMC 85-13 573.7 9.56 337.7 12 13 174.0 188.5 1550 1462 x 1952 x 1060
TMC 86 – 8 EWA/EWNA 857.2 14.29 504.5 7 8 101.5 116.0 1590 1158 x 1829 x 2201
TMC 86 – 10 EWA/EWNA 760.5 12.67 447.6 9 10 130.5 145.0 1590 1158 x 1829 x 2201
TMC 86 – 13 EWA/EWNA 664.9 11.08 391.4 12 13 174 188.5 1590 1158 x 1829 x 2201
TMC 99 – 8 EWA/EWNA 1064.2 17.74 626.4 7 8 101.5 116.0 1740 1158 x 1829 x 2201
TMC 99 – 10 EWA/EWNA 945.0 15.75 556.2 9 10 130.5 145.0 1740 1158 x 1829 x 2201
TMC 99 – 13 EWA/EWNA 825.6 13.76 485.9 12 13 174.0 188.5 1740 1158 x 1829 x 2201
TMC 124 – 8 EWA/EWNA 1143.1 19.05 672.8 7 8 101.5 116.0 1780 1158 x 1829 x 2201
TMC 124 – 10 EWA/EWNA 1054.4 17.57 620.6 9 10 130.5 145.0 1780 1158 x 1829 x 2201
TMC 124 – 13 EWA/EWNA 892.1 14.87 525.1 12 13 174.0 188.5 1780 1158 x 1829 x 2201
TMC 150-8 EWA/EWNA 1356.0 22.6 798.1 7 8 101.5 116.0 2600/2800 * 990 x 1900 x 3000
TMC 150-10 EWA/EWNA 1290.0 21.5 759.3 9 10 130.5 145.0 2600/2800 * 990 x 1900 x 3000
TMC 150-13 EWA/EWNA 1068.0 17.8 628.6 12 13 174.0 188.5 2600/2800 * 990 x 1900 x 3000
TMC 185-8 EWA/EWNA 1656.0 27.6 974.7 7 8 101.5 116.0 2700/2900 * 990 x 1900 x 3000
TMC 185-10 EWA/EWNA 1494.0 24.9 879.3 9 10 130.5 145.0 2700/2900 * 990 x 1900 x 3000
TMC 185-13 EWA/EWNA 1302.0 21.7 766.3 12 13 174.0 188.5 2700/2900 * 990 x 1900 x 3000
TMC 235-10 EWA/EWNA 1788.0 29.8 1052.4 9 10 130.5 145.0 2700/2900 * 990 x 1900 x 3000
TMC 235-13 EWA/EWNA 1560.0 26.0 918.2 12 13 174.0 188.5 2700/2900 * 990 x 1900 x 3000
TMC 240-8 EWA/EWNA 2262.0 37.7 1331.4 7 8 101.5 116.0 3900/4000 * 1480 x 2165 x 3368
TMC 240-10 EWA/EWNA 2070.0 34.5 1218.4 9 10 130.5 145.0 3900/4000 * 1480 x 2165 x 3368
TMC 240-13 EWA/EWNA 1692.0 28.2 995.9 12 13 174.0 188.5 3900/4000 * 1480 x 2165 x 3368
TMC 290-8 EWA/EWNA 2796.0 46.6 1645.7 7 8 101.5 116.0 4280/4380 * 1480 x 2165 x 3368
TMC 290-10 EWA/EWNA 2520.0 42.0 1483.2 9 10 130.5 145.0 4150/4250 * 1480 x 2165 x 3368
TMC 290-13 EWA/EWNA 2142.0 35.7 1260.7 12 13 174.0 188.5 4150/4250 * 1480 x 2165 x 3368
TMC 365-8 EWA/EWNA 3102.0 51.7 1825.8 7 8 101.5 116.0 4500/4600 * 1480 x 2165 x 3368
TMC 365-10 EWA/EWNA 2940.0 49.0 1730.4 9 10 130.5 145.0 4500/4600 * 1480 x 2165 x 3368
TMC 365-13 EWA/EWNA 2604.0 43.4 1532.7 12 13 174.0 188.5 4350/4450 * 1480 x 2165 x 3368
TMC 400 – 8 EWA/EWNA 3769.9 62.8 2218.9 7 8 101.52 116.03 6000/6300 * 1384x2170x3900
TMC 400 – 9 EWA/EWNA 3629.2 60.49 2136.1 8 9 116.03 130.53 6000/6300 * 1384x2170x3900
TMC 400 – 10 EWA/EWNA 3366.0 56.1 1981.2 9 10 130.53 145.03 6000/6300 * 1384x2170x3900
TMC 400 – 11 EWA/EWNA 3151.8 52.5 1854.1 10 11 145.03 159.54 6000/6300 * 1384x2170x3900
TMC 400 – 12 EWA/EWNA 2994.0 49.9 1762.2 11 12 159.54 174.04 6000/6300 * 1384x2170x3900
TMC 400 – 13 EWA/EWNA 2880.0 48.0 1695.1 12 13 174.04 188.54 6000/6300 * 1384x2170x3900
TMC 450 – 8 EWA/EWNA 4155.5 69.3 2447.3 7 8 101.52 116.03 6000/6300 * 1384x2170x3900
TMC 450 – 9 EWA/EWNA 4008.6 66.81 2359.4 8 9 116.03 130.53 6000/6300 * 1384x2170x3900
TMC 450 – 10 EWA/EWNA 3739.3 62.3 2200.9 9 10 130.53 145.03 6000/6300 * 1384x2170x3900
TMC 450 – 11 EWA/EWNA 3594.0 59.9 2115.3 10 11 145.03 159.54 6000/6300 * 1384x2170x3900
TMC 450 – 12 EWA/EWNA 3336.0 55.6 1963.5 11 12 159.54 174.04 6000/6300 * 1384x2170x3900
TMC 450 – 13 EWA/EWNA 3210.0 53.5 1889.3 12 13 174.04 188.54 6000/6300 * 1384x2170x3900
* Weight EWA/EWNA (EWNA = With canopy, EWA = Without canopy)

TMC Smart Air® Compressors – Entire Range

Type and Motor KW Capacity (nom.press.) Capacity (nom.press.) Capacity (nom.press.) Nominal Pressure Max Pressure Nominal Pressure Max Pressure Weight Dimensions
m3/h m3/min c.f.m bar bar psi psi kg mm (WxHxD)
TMC 21 SA – 7.5 34.2-213 0.57-3.55 20.1-125.4 7 7.5 101.5 108.8 435 993 x 1256 x 728
TMC 21 SA – 10 31.8-192 0.53-3.20 18.7-113 9 10 130.5 145 435 993 x 1256 x 728
TMC 21 SA – 13 27-159.6 0.45-2.66 15.9-93.9 12 13 174 188.5 435 993 x 1256 x 728
TMC 30 – SA 7.5 65.4-300.6 1.09-5.01 38.5-176.9 7 7.5 101.5 108.8 700 701 x 1700 x 1006
TMC 30 SA – 10 60.6-268.2 1.01-4.47 35.7-157.9 9 10 130.5 145 700 701 x 1700 x 1006
TMC 30 SA – 13 55.2-220.8 0.92-3.68 32.5-130 12 13 174 188.5 700 701 x 1700 x 1006
TMC 40 SA – 7.5 69.6-394.8 1.16-6.58 41-232.4 7 7.5 101.5 108.8 750 701 x 1700 x 1006
TMC 40 SA – 10 66-359.4 1.10-5.99 38.8-211.5 9 10 130.5 145 750 701 x 1700 x 1006
TMC 40 SA – 13 58.8-309 0.98-5.15 34.6-181.9 12 13 174 188.5 750 701 x 1700 x 1006
TMC 60 SA – 7.5 91.8-574.8 1.53-9.58 54-338.3 7 7.5 101.5 108.8 1380 1462 x 1952 x 1060
TMC 60 SA – 10 89.4-540.6 1.49-9.01 52.6-318.2 9 10 130.5 145 1380 1462 x 1952 x 1060
TMC 60 SA – 13 75.6-475.8 1.26-7.93 44.5-280 12 13 174 188.5 1380 1462 x 1952 x 1060
TMC 80 SA – 7.5 108.6-720 1.81-12.00 63.9-423.8 7 7.5 101.5 108.8 1500 1462 x 1952 x 1060
TMC 80 SA – 10 103.8-657 1.73-10.95 61.1-386.7 9 10 130.5 145 1500 1462 x 1952 x 1060
TMC 80 SA – 13 94.8-550.8 1.58-9.18 55.8-324.2 12 13 174 188.5 1500 1462 x 1952 x 1060
TMC 95 SA – 7.5 198-1104 3.3-18.4 116.5-649.8 7 7.5 101.5 108.8 1890 1158 x 1829 x 2201
TMC 95 SA – 10 192-1002 3.2-16.7 113.0 – 589.8 9 10 130.5 145 1890 1158 x 1829 x 2201
TMC 95 SA – 13 276-864 4.6-14.4 162.5 – 508.6 12 13 174 188.5 1890 1158 x 1829 x 2201
TMC 125 SA – 8 226.2-1177 3.8-19.6 113.2-692.8 7 8 101.5 116.0 2750 990 x 1900 x 3000
TMC 125 SA – 10 219-1035 3.70-17.3 128.9-609.2 9 10 130.5 145 2750 990 x 1900 x 3000
TMC 125 SA – 13 201-870 3.40-14.5 118.3-512.1 12 13 174 188.5 2750 990 x 1900 x 3000
TMC 150 SA – 8 282-1410 4.70–23.50 165.9-829.8 7 8 101.5 116.0 2850 990 x 1900 x 3000
TMC 150 SA – 10 324-1254 5.40–20.90 190.6-738 9 10 130.5 145 2850 990 x 1900 x 3000
TMC 150 SA – 13 252.6-975 4.20–16.30 148.6-573.8 12 13 174.0 188.5 2850 990 x 1900 x 3000
TMC 235 SA – 8 408-1722 6.80–28.70 240.1-1013.5 7 8 101.5 116 2700 990 x 1900 x 3000
TMC 235 SA – 10 396-1680 6.60–28.00 233-988.8 9 10 130.5 145 2700 990 x 1900 x 3000
TMC 235 SA – 13 390-1542 6.50–25.70 229.5-907.5 12 13 174.0 188.5 2700 990 x 1900 x 3000
TMC 240 SA – 8 372-1974 6.20-32.90 219-1161.9 7 8 101.5 116 4000 1480 x 2165 x 3370
TMC 240 SA – 10 342-1788 5.70-29.80 201.3-1052.4 9 10 130.5 145 4000 1480 x 2165 x 3370
TMC 240 SA – 13 720-1464 12.00-24.40 423.8-861.7 12 13 174 188.5 4000 1480 x 2165 x 3370
TMC 290 SA – 8 576-2514 9.60-41.90 339-1479.5 7 8 101.5 116 4250 1480 x 2165 x 3370
TMC 290 SA – 10 594-2322 9.90-38.70 349.6-1366.6 9 10 130.5 145 4250 1480 x 2165 x 3370
TMC 290 SA – 13 684-1950 11.40-32.50 402.5-1147.7 12 13 174 188.5 4250 1480 x 2165 x 3370
TMC 365 SA – 8 660-3000 11.00-50.00 388.5-1765.8 7 8 101.5 116 4600 1480 x 2165 x 3370
TMC 365 SA – 10 642-2742 10.70-45.70 377.9-1614 9 10 130.5 145 4600 1480 x 2165 x 3370
TMC 365 SA – 13 804-2346 13.40-39.10 473.2-1380.9 12 13 174 188.5 4450 1480 x 2165 x 3370
General information – all models: Compressors up to 10 kW come as air cooled only. Compressors from 15 to 85 kW are available as air cooled or fresh water cooled as standard, and as sea water cooled on request. Units above 85 kW are fresh water cooled as standard. Air and sea water cooling available for some units upon request. Capacities measured according to Cagi Pneurop PN2CPTC2. Capacity data given at 45°C ambient conditions for electric motors with 440 V/60 Hz. Design temperature for all components is minimum 55°C. Capacities and dimensions are subject to change without notice. Before installation, obtain correct dimensions from technical drawings.